Automated optic chiasm segmentation in MRI of human patients with multiple sclerosis
In a study involving 58 patients with relapsing-remitting MS, a multi-view, multi-class 2D U-Net framework was tested for optic chiasm segmentation. This model showed stable convergence and the best performance among all models evaluated, achieving a Dice similarity coefficient (DSC) of 91.28% and significant improvements over single-view models.
- Tags
- #MSResearch
- Most relevant to
- —
- Human efficacy
- Not established from this source
- Mechanism
- Not reported
- Evidence strength
- Not graded
- Outcome
- Not reported
Why it matters
Improving segmentation performance in MRI could enhance diagnosis and monitoring of MS, particularly for small and complex structures like the optic chiasm, which are crucial for visual pathways.
What this does not prove
Despite the improvements, accurate segmentation remains challenging due to the small size, complex anatomy, and noticeable foreground-background imbalance of the optic chiasm.
Next milestone
No next milestone was established from the available source.
Study facts
- Study design
- Not reported
- Participants / samples
- 58 · basis not reported
- Randomised
- Not reported
- Controlled
- Not reported
- Primary endpoint met
- Not reported
- Relevant MS type
- Not reported
- Publication date
- 2026-10-10
- Evidence reviewed
- Abstract only
- Regulatory approval
- Not reported
- Research areas
- Not classified
- Biological target
- Not reported
- Pathway
- Not reported
- Population
- 58 patients with relapsing-remitting MS
- Size of effect
- DSC of 91.28%, IoU of 84.05%, balanced accuracy of 94.43%
- Secondary endpoints
- Not reported
- MRI endpoints
- Not reported
- Biomarkers
- Not reported
- Safety
- Not reported
Original sources
- Primary evidenceAutomated optic chiasm segmentation in magnetic resonance imaging of multiple sclerosis patients using a multi-view, multi-class U-Net with limited annotated data. ↗DOI: 10.4103/jrms.jrms_151_26
Supporting passages (11)
publication datePublication date: 2026-10-10
interventionCONCLUSION: The proposed multi-view, multi-class 2D U-Net framework outperformed conventional single-view models for optic chiasm segmentation.
comparatorCONCLUSION: The proposed multi-view, multi-class 2D U-Net framework outperformed conventional single-view models for optic chiasm segmentation.
primary endpointSegmentation performance was assessed quantitatively using multiple metrics, with the Dice similarity coefficient (DSC), intersection over union (IoU), and balanced accuracy serving as the primary evaluation metrics, and qualitatively through visual comparison with expert annotations.
findingsThe proposed multi-view model demonstrated stable convergence and achieved the highest segmentation performance among all evaluated models, with a DSC of 91.28%, IoU of 84.05%, and balanced accuracy of 94.43%.
limitationsHowever, accurate segmentation remains challenging because of the structure's small size, complex anatomy, and marked foreground-background imbalance.
populationRESULTS: A total of 58 patients with relapsing-remitting MS were included in the analysis.
effect sizeThe proposed multi-view model demonstrated stable convergence and achieved the highest segmentation performance among all evaluated models, with a DSC of 91.28%, IoU of 84.05%, and balanced accuracy of 94.43%.
peer reviewedPublication types: Journal Article
sample sizeRESULTS: A total of 58 patients with relapsing-remitting MS were included in the analysis. The proposed multi-view model demonstrated stable convergence and achieved the highest segmentation performance among all evaluated models, with a DSC of 91.28%, IoU of 84.05%, and balanced accuracy of 94.43%. Compared with the best-performing single-view model, the multi-view approach improved DSC and IoU by approximately 13 and 19 percentage points, respectively. Qualitative assessment showed closer agreement between multi-view segmentations and expert annotations.
subjectsTitle: Automated optic chiasm segmentation in magnetic resonance imaging of multiple sclerosis patients using a multi-view, multi-class U-Net with limited annotated data.
AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.