Detection of Central Vein Sign in Human MS Patients using Optimized SWI
In a study with 17 patients diagnosed with MS, optimized susceptibility weighted imaging (SWI) detected 105 lesions compared to 72 detected by standard SWI, also increasing the positive detection rate of MS to 82.4% from 41.2%. The optimized method outperformed the standard in detecting lesions in 14 of the 17 participants.
- Tags
- #MSResearch
- Most relevant to
- —
- Human efficacy
- Not established from this source
- Mechanism
- Not reported
- Evidence strength
- Not graded
- Outcome
- Positive
Why it matters
This advancement in imaging technique could enhance the diagnosis of multiple sclerosis by increasing the detection rate of critical lesions, potentially influencing treatment approaches.
What this does not prove
The study does not assess long-term impacts or outcomes linked to the improved detection of lesions.
Next milestone
No next milestone was established from the available source.
Study facts
- Study design
- Not reported
- Participants / samples
- 17 · number of patients scanned
- Randomised
- Not reported
- Controlled
- Not reported
- Primary endpoint met
- Not reported
- Relevant MS type
- Not reported
- Publication date
- 2026-11-18
- Evidence reviewed
- Abstract only
- Regulatory approval
- Not reported
- Research areas
- Not classified
- Biological target
- Not reported
- Pathway
- Not reported
- Population
- seventeen patients with a clinical diagnosis of MS
- Size of effect
- Not reported
- Secondary endpoints
- Not reported
- MRI endpoints
- Not reported
- Biomarkers
- Not reported
- Safety
- Not reported
Original sources
- Primary evidenceImproved detection of central vein sign in multiple sclerosis using optimized susceptibility weighted imaging at 3 Tesla. ↗DOI: 10.1007/s00330-026-13069-3
Supporting passages (14)
subjectsMATERIALS AND METHODS: Seventeen patients with a clinical diagnosis of MS were scanned on a 3 T MRI scanner using a standard SWI and an optimized SWI acquired with a lower flip angle (FA = 5°).
sample size17
sample size basisMATERIALS AND METHODS: Seventeen patients with a clinical diagnosis of MS were scanned on a 3 T MRI scanner using a standard SWI and an optimized SWI acquired with a lower flip angle (FA = 5°).
publication date2026-11-18
interventionMATERIALS AND METHODS: Seventeen patients with a clinical diagnosis of MS were scanned on a 3 T MRI scanner using a standard SWI and an optimized SWI acquired with a lower flip angle (FA = 5°).
comparatorstandard SWI
primary endpointKEY POINTS: Question Standard SWI can visualize venous structures at 3 T, but provides limited lesion conspicuity, which prevents standalone detection of the central vein sign (CVS).
findingsOptimized SWI detected all CVS+ lesions identified by standard SWI plus 33 additional lesions (105 vs. 72).
findingsOptimized SWI detected more CVS+ lesions than standard SWI in 14/17 participants, with a higher median number of CVS+ lesions detected per participant (7.0 vs. 4.0; p < 0.001).
findingsPositive detection rate for MS using Select-6 increased from 41.2% with standard SWI to 82.4% with optimized SWI (p = 0.016).
populationMATERIALS AND METHODS: Seventeen patients with a clinical diagnosis of MS were scanned on a 3 T MRI scanner using a standard SWI and an optimized SWI acquired with a lower flip angle (FA = 5°).
outcomePositive
limitationsTitle: Improved detection of central vein sign in multiple sclerosis using optimized susceptibility weighted imaging at 3 Tesla.
peer reviewedPublication types: Journal Article
AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.