Diagnostic Performance of the KFLC Index in Patients with Multiple Sclerosis
In a study of 140 patients, the KFLC index showed a significantly higher value in those with multiple sclerosis (MS) compared to those without. The analysis indicated strong diagnostic accuracy for the KFLC index, with a cut-off value yielding 89.1% sensitivity and 96.0% specificity.
- Tags
- #MSResearch
- Most relevant to
- —
- Human efficacy
- Not established from this source
- Mechanism
- Not reported
- Evidence strength
- Limited
- Outcome
- Not reported
Why it matters
These findings suggest that the KFLC index may be a reliable diagnostic tool for differentiating MS from other neurological disorders, potentially enhancing diagnostic accuracy in clinical practice.
What this does not prove
The study was conducted at a single center, which may limit the generalizability of the results. Larger multicenter studies are needed to validate these findings.
Next milestone
No next milestone was established from the available source.
Study facts
- Study design
- Observational
- Participants / samples
- 140 · basis not reported
- Randomised
- Not reported
- Controlled
- Not reported
- Primary endpoint met
- Not reported
- Relevant MS type
- Not reported
- Publication date
- 2026-11-20
- Evidence reviewed
- Abstract only
- Regulatory approval
- Not reported
- Research areas
- Not classified
- Biological target
- Not reported
- Pathway
- Not reported
- Population
- 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up, including 64 patients with MS and 76 with other neurological disorders.
- Size of effect
- Not reported
- Secondary endpoints
- Not reported
- MRI endpoints
- Not reported
- Biomarkers
- Not reported
- Safety
- Not reported
Original sources
- Primary evidenceDo we have an appropriate cut-off for the kappa free light chain index in multiple sclerosis diagnosis? a real-world single-center comparison with oligoclonal bands. ↗DOI: 10.1016/j.jocn.2026.112405
Supporting passages (9)
sample size140
publication date2026-11-20
primary endpointWe aimed to evaluate the diagnostic performance of the KFLC index in a real-world neurological cohort, compare it with oligoclonal bands (OCBs), and determine a locally optimal cut-off value.
findingsThe KFLC index was significantly higher in patients with MS than in non-MS patients [median 43.4 (IQR 16.6-88.1) vs. 1.8 (IQR 1.4-2.8), p<0.001]. ROC analysis showed high diagnostic accuracy for the KFLC index, with an AUC of 0.954 (95% CI 0.919-0.990), compared with 0.831 (95% CI 0.756-0.905) for OCB status. A locally optimal KFLC index cut-off of 9.3 yielded 89.1% sensitivity, 96.0% specificity, a positive predictive value of 95.0%, a negative predictive value of 91.3%, and an overall accuracy of 92.9%. OCB positivity was observed in 68.8% of MS patients and 2.6% of non-MS patients.
populationMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.
limitationsTitle: Do we have an appropriate cut-off for the kappa free light chain index in multiple sclerosis diagnosis? a real-world single-center comparison with oligoclonal bands.
peer reviewedPublication types: Journal Article
study designMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.
subjectsMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.
AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.