Skip to content
Back to feed
AI CuratorAI-generated
Research summary ·
AI summary · not yet reviewedHuman studyObservationalPublished in a peer-reviewed journal

Diagnostic Performance of the KFLC Index in Patients with Multiple Sclerosis

In a study of 140 patients, the KFLC index showed a significantly higher value in those with multiple sclerosis (MS) compared to those without. The analysis indicated strong diagnostic accuracy for the KFLC index, with a cut-off value yielding 89.1% sensitivity and 96.0% specificity.

Most relevant to
—
This plain-English summary was written by AI from a published abstract and may contain errors. It is not medical advice. Read the original study and talk to your MS team before making decisions about treatment.
Human efficacy
Not established from this source
Mechanism
Not reported
Evidence strength
Limited
Outcome
Not reported

Why it matters

These findings suggest that the KFLC index may be a reliable diagnostic tool for differentiating MS from other neurological disorders, potentially enhancing diagnostic accuracy in clinical practice.

What this does not prove

The study was conducted at a single center, which may limit the generalizability of the results. Larger multicenter studies are needed to validate these findings.

Next milestone

No next milestone was established from the available source.

Study facts
Study design
Observational
Participants / samples
140 · basis not reported
Randomised
Not reported
Controlled
Not reported
Primary endpoint met
Not reported
Relevant MS type
Not reported
Publication date
2026-11-20
Evidence reviewed
Abstract only
Regulatory approval
Not reported
Research areas
Not classified
Biological target
Not reported
Pathway
Not reported
Population
140 patients who underwent lumbar puncture during routine neurological diagnostic work-up, including 64 patients with MS and 76 with other neurological disorders.
Size of effect
Not reported
Secondary endpoints
Not reported
MRI endpoints
Not reported
Biomarkers
Not reported
Safety
Not reported

Original sources

Supporting passages (9)
sample size140
publication date2026-11-20
primary endpointWe aimed to evaluate the diagnostic performance of the KFLC index in a real-world neurological cohort, compare it with oligoclonal bands (OCBs), and determine a locally optimal cut-off value.
findingsThe KFLC index was significantly higher in patients with MS than in non-MS patients [median 43.4 (IQR 16.6-88.1) vs. 1.8 (IQR 1.4-2.8), p<0.001]. ROC analysis showed high diagnostic accuracy for the KFLC index, with an AUC of 0.954 (95% CI 0.919-0.990), compared with 0.831 (95% CI 0.756-0.905) for OCB status. A locally optimal KFLC index cut-off of 9.3 yielded 89.1% sensitivity, 96.0% specificity, a positive predictive value of 95.0%, a negative predictive value of 91.3%, and an overall accuracy of 92.9%. OCB positivity was observed in 68.8% of MS patients and 2.6% of non-MS patients.
populationMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.
limitationsTitle: Do we have an appropriate cut-off for the kappa free light chain index in multiple sclerosis diagnosis? a real-world single-center comparison with oligoclonal bands.
peer reviewedPublication types: Journal Article
study designMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.
subjectsMETHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up.

AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.

0

Discussion 0 comments

Log in or join to comment.