Evaluation of Black Hole Segmentation in People with Multiple Sclerosis

This study assessed a new method for segmenting black holes in MRI scans of 88 people with multiple sclerosis (pwMS). The optimal threshold identified was 0.95 times the median cGM intensity. In validation, the median black hole volume was 1.54 mL for the new method and 1.24 mL for a reference method, with certain statistical measures indicating good performance of the new approach.

Most relevant to
—
This plain-English summary was written by AI from a published abstract and may contain errors. It is not medical advice. Read the original study and talk to your MS team before making decisions about treatment.
Human efficacy
Not established from this source
Mechanism
Not reported
Evidence strength
Not graded
Outcome
Not reported

Why it matters

Accurate identification of black holes in MS imaging is vital for monitoring disease progression. Developing validated segmentation methods enhances our capability to track severe tissue damage in pwMS.

What this does not prove

Currently, there is no validated segmentation method for contemporary 3D T1-weighted gradient-echo acquisitions beyond this study's findings.

Next milestone

No next milestone was established from the available source.

Study facts
Study design
Not reported
Participants / samples
Not reported
Randomised
Not reported
Controlled
Not reported
Primary endpoint met
Not reported
Relevant MS type
Not reported
Publication date
2026-11-25
Evidence reviewed
Abstract only
Regulatory approval
Not reported
Research areas
Not classified
Biological target
Not reported
Pathway
Not reported
Population
people with multiple sclerosis (pwMS)
Size of effect
ICC of 0.92 and DSC of 0.59 relative to a 2D T1-weighted reference
Secondary endpoints
Not reported
MRI endpoints
Not reported
Biomarkers
Not reported
Safety
Not reported

Original sources

Supporting passages (7)
populationMATERIALS AND METHODS: Eighty-eight pwMS with 2DT1w SE, 3DT1w GRE, and 3D-FLAIR scans were selected from the Amsterdam MS cohort.
findingsIn the validation set, median BH volume was 1.54 mL (IQR: 0.80-2.57 mL) for 3DBHSeg and 1.24 mL (IQR: 0.65-2.47 mL) for the 2DT1w reference, with a hybrid score of 0.76, an ICC (absolute agreement) of 0.92 (95% CI [0.87-0.95]), and a mean DSC of 0.59 ± 0.10.
limitationsKEY POINTS: Question Black holes reflect areas of severe tissue damage in multiple sclerosis, yet no validated segmentation method exists for contemporary 3D T1-weighted gradient-echo acquisitions.
effect sizeICC of 0.92 and DSC of 0.59 relative to a 2D T1-weighted reference.
publication datePublication date: 2026-11-25
peer reviewedPublication types: Journal Article
subjectsMATERIALS AND METHODS: Eighty-eight pwMS with 2DT1w SE, 3DT1w GRE, and 3D-FLAIR scans were selected from the Amsterdam MS cohort.

AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.

0

Discussion 0 comments

Log in or join to comment.