Impact of Slice Orientation on Susceptibility-Weighted Imaging in MS Patients
In a study with 26 MS patients using a 1.5 T scanner, it was found that phase magnitudes in susceptibility-weighted imaging were significantly higher with zero alignment compared to conventional anatomical alignment (p < 0.05), indicating that orientation affects imaging outcomes.
- Tags
- #MSResearch
- Most relevant to
- —
- Human efficacy
- Not established from this source
- Mechanism
- Not reported
- Evidence strength
- Limited
- Outcome
- Positive
Why it matters
These findings suggest that current practices for anatomical alignment in imaging may limit the detection of key susceptibility-related biomarkers in MS.
What this does not prove
Only one scanner type was used and the sample size was small, potentially affecting the generalizability of results.
Next milestone
No next milestone was established from the available source.
Study facts
- Study design
- Interventional
- Participants / samples
- 26 · number of patients with multiple sclerosis
- Randomised
- No
- Controlled
- Not reported
- Primary endpoint met
- Not reported
- Relevant MS type
- Not reported
- Publication date
- 2026-11-20
- Evidence reviewed
- Abstract only
- Regulatory approval
- Not reported
- Research areas
- Not classified
- Biological target
- Not reported
- Pathway
- Not reported
- Population
- Twenty-six MS patients
- Size of effect
- Not reported
- Secondary endpoints
- Not reported
- MRI endpoints
- Not reported
- Biomarkers
- Not reported
- Safety
- Not reported
Original sources
- Primary evidenceSlice orientation impacts phase values in susceptibility weighted imaging of the deep gray matter in patients with multiple sclerosis. ↗DOI: 10.1016/j.mri.2026.110850
Supporting passages (17)
study phasePhase quantification has emerged as a critical method for monitoring disease progression and evaluating treatment efficacy in Multiple Sclerosis (MS) due to its high sensitivity to pathological iron deposition and microstructural changes.
study designThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
subjectsThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
speciesThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
sample sizeThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
sample size basisThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
randomizedThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
peer reviewedJournal Article
interventionThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
comparatorconventional anatomical alignment.
primary endpointTitle: Slice orientation impacts phase values in susceptibility weighted imaging of the deep gray matter in patients with multiple sclerosis.
findingsQuantitative ROI analysis across seven bilateral deep gray matter structures revealed that phase magnitudes were consistently and significantly higher under zero alignment compared to anatomical alignment (p < 0.05).
populationThis prospective study evaluated the impact of such orientation variations on Susceptibility-Weighted Angiography (SWAN) phase values in twenty-six MS patients using a 1.5 T scanner.
outcomeThese findings suggest that current anatomical alignment practices may sub-optimize the detection of susceptibility-related biomarkers.
publication datePublication date: 2026-11-20
limitationsTitle: Slice orientation impacts phase values in susceptibility weighted imaging of the deep gray matter in patients with multiple sclerosis.
peer reviewedPublication types: Journal Article
AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.