Kappa Free Light Chain Index in Multiple Sclerosis Patients
In a study involving 73 MS patients and 214 controls, the Kappa Free Light Chain (KFLC) Index displayed a significantly higher median in MS patients compared to controls. It achieved an area under the curve (AUC) of 0.978, indicating strong diagnostic performance, with 100% sensitivity and 93% specificity at a cut-off of ≥7.49.
- Tags
- #MSResearch
- Most relevant to
- —
Why it matters
These findings suggest that the KFLC Index could be a superior diagnostic tool for MS compared to traditional methods like the IgG Index and OCB.
What this does not prove
The study's retrospective nature and single-center design limit its generalizability. Additionally, elevated KFLC Index levels were also found in non-MS conditions, warranting further research on specificity.
Next milestone
No next milestone was established from the available source.
Study facts
- Study design
- Observational
- Participants / samples
- 287 · Total number of participants (73 MS patients and 214 controls)
- Randomised
- Not reported
- Controlled
- Not reported
- Primary endpoint met
- Yes
- Relevant MS type
- Not reported
- Publication date
- 2026-10-02
- Evidence reviewed
- Abstract only
- Regulatory approval
- Not reported
- Research areas
- Not classified
Original sources
- Primary evidenceCorrelation and diagnostic accuracy of kappa free light chain index and Oligoclonal bands in multiple sclerosis and other neurological diseases. ↗DOI: 10.1016/j.msard.2026.107956
Supporting passages (10)
study designIn this single-center retrospective study, 73 MS patients and 214 controls (n = 287) were evaluated via Mann-Whitney U test and Receiver Operating Characteristic (ROC) analysis.
subjectsMATERIALS AND METHODS: In this single-center retrospective study, 73 MS patients and 214 controls (n = 287) were evaluated via Mann-Whitney U test and Receiver Operating Characteristic (ROC) analysis.
sample sizeMATERIALS AND METHODS: In this single-center retrospective study, 73 MS patients and 214 controls (n = 287) were evaluated via Mann-Whitney U test and Receiver Operating Characteristic (ROC) analysis.
sample size basisMATERIALS AND METHODS: In this single-center retrospective study, 73 MS patients and 214 controls (n = 287) were evaluated via Mann-Whitney U test and Receiver Operating Characteristic (ROC) analysis.
primary endpoint metThe KFLC Index provides exceptional quantitative sensitivity and specificity in MS diagnosis.
comparatorWe evaluated the diagnostic performance of cerebrospinal fluid (CSF) Kappa Free Light Chain (KFLC) Index compared to conventional Oligoclonal Bands (OCB) and IgG Index.
primary endpointWe evaluated the diagnostic performance of cerebrospinal fluid (CSF) Kappa Free Light Chain (KFLC) Index compared to conventional Oligoclonal Bands (OCB) and IgG Index.
findingsRESULTS: The median KFLC Index was significantly higher in MS (45.81, IQR: 26.36-144.54) than controls (2.27, IQR: 1.74-3.11; p < 0.0001).
publication datePublication date: 2026-10-02
limitationsTitle: Correlation and diagnostic accuracy of kappa free light chain index and Oligoclonal bands in multiple sclerosis and other neurological diseases.
AI assessment, not yet reviewed by a person · version 1 · Community votes are separate from evidence review.